{"id":75272,"date":"2026-09-12T14:29:55","date_gmt":"2026-09-12T17:29:55","guid":{"rendered":"https:\/\/a3aengenharia.com\/?post_type=articles&#038;p=75272"},"modified":"2026-09-12T14:29:55","modified_gmt":"2026-09-12T17:29:55","slug":"grados-proteccion-ip-ik-control-acceso-lectores-equipos","status":"publish","type":"articles","link":"https:\/\/a3aengenharia.com\/es-es\/contenido\/articulos-tecnicos\/grados-proteccion-ip-ik-control-acceso-lectores-equipos\/","title":{"rendered":"Grados de protecci\u00f3n IP e IK en control de acceso: c\u00f3mo especificar lectores y equipos"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">El <strong>grado de protecci\u00f3n IP<\/strong> indica la protecci\u00f3n proporcionada por la envolvente contra el acceso a partes peligrosas y la entrada de cuerpos s\u00f3lidos y agua, conforme a IEC 60529. El <strong>grado de protecci\u00f3n IK<\/strong>, por su parte, clasifica la resistencia de la envolvente a impactos mec\u00e1nicos externos, conforme a IEC 62262. En control de acceso, estas clasificaciones ayudan a seleccionar lectores, interfaces, intercomunicadores, pulsadores, gabinetes y otros dispositivos para el entorno en el que realmente ser\u00e1n instalados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque b\u00fasquedas como <strong>clasificaci\u00f3n IP<\/strong>, <strong>\u00edndice de protecci\u00f3n IP<\/strong>, <strong>IP65 vs. IP66<\/strong>, <strong>clasificaci\u00f3n IK<\/strong> e <strong>IP IK<\/strong> son comunes, IP e IK no son sellos gen\u00e9ricos de \u201crobustez\u201d. Cada c\u00f3digo responde a un tipo espec\u00edfico de exposici\u00f3n. Un lector IP65 puede ser adecuado para lluvia y polvo, pero aun as\u00ed requerir an\u00e1lisis de temperatura, radiaci\u00f3n solar, corrosi\u00f3n, vandalismo, condensaci\u00f3n, instalaci\u00f3n, cableado y mantenimiento. Del mismo modo, IK10 no informa nada sobre estanqueidad al agua.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IP e IK miden riesgos diferentes<\/h2>\n\n\n\n<div class=\"wp-block-a3a-destaque\">\n<p class=\"wp-block-paragraph\">IP e IK deben definirse a partir del entorno y del riesgo de cada punto. Copiar la clase m\u00e1s alta del cat\u00e1logo puede aumentar el costo sin resolver el problema real.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/planejamento\/projeto-de-controle-de-acesso\/\">Conozca el Proyecto de Control de Acceso<\/a><\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">La primera decisi\u00f3n de proyecto es no mezclar los dos c\u00f3digos. <strong>IP<\/strong> est\u00e1 relacionado con la envolvente frente a s\u00f3lidos y agua. <strong>IK<\/strong> est\u00e1 relacionado con la energ\u00eda de impacto mec\u00e1nico soportada por la envolvente en las condiciones de ensayo previstas por la norma.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>C\u00f3digo<\/td><td>Qu\u00e9 clasifica<\/td><td>Pregunta de proyecto<\/td><\/tr><tr><td>IP<\/td><td>entrada de s\u00f3lidos y agua<\/td><td>\u00bfla envolvente es adecuada para la exposici\u00f3n ambiental?<\/td><\/tr><tr><td>IK<\/td><td>impacto mec\u00e1nico externo<\/td><td>\u00bfel equipo soporta la exposici\u00f3n f\u00edsica prevista?<\/td><\/tr><tr><td>Temperatura<\/td><td>rango de operaci\u00f3n del equipo<\/td><td>\u00bffuncionar\u00e1 con el calor\/fr\u00edo real del lugar?<\/td><\/tr><tr><td>Corrosi\u00f3n\/material<\/td><td>resistencia al ambiente qu\u00edmico o salino<\/td><td>\u00bfla envolvente y las fijaciones soportan el ambiente?<\/td><\/tr><tr><td>UV<\/td><td>estabilidad bajo radiaci\u00f3n solar<\/td><td>\u00bflos materiales externos se degradar\u00e1n prematuramente?<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un buen proyecto utiliza estas propiedades de forma conjunta. No existe una \u00fanica clase IP o IK correcta para todo sistema de control de acceso.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">C\u00f3mo leer la clasificaci\u00f3n IP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El c\u00f3digo IP normalmente tiene dos d\u00edgitos despu\u00e9s de las letras IP. El <strong>primer d\u00edgito<\/strong> representa el grado de protecci\u00f3n relacionado con el acceso a partes peligrosas y la entrada de objetos s\u00f3lidos. El <strong>segundo<\/strong> representa la protecci\u00f3n contra la entrada de agua en las condiciones de ensayo correspondientes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En la pr\u00e1ctica del control de acceso, algunas combinaciones aparecen con frecuencia:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Ejemplo<\/td><td>Interpretaci\u00f3n general<\/td><td>Aplicaci\u00f3n posible<\/td><\/tr><tr><td>IP54<\/td><td>protecci\u00f3n contra polvo en un nivel definido y salpicaduras de agua<\/td><td>\u00e1rea protegida, sujeta a polvo y salpicaduras<\/td><\/tr><tr><td>IP55<\/td><td>protecci\u00f3n contra polvo y chorros de agua<\/td><td>equipo exterior con exposici\u00f3n moderada<\/td><\/tr><tr><td>IP65<\/td><td>estanco al polvo y protegido contra chorros de agua<\/td><td>lector exterior expuesto a la intemperie seg\u00fan las condiciones previstas<\/td><\/tr><tr><td>IP66<\/td><td>estanco al polvo y protegido contra chorros potentes<\/td><td>exposici\u00f3n m\u00e1s severa a agua proyectada<\/td><\/tr><tr><td>IP67<\/td><td>estanco al polvo y protegido para una condici\u00f3n definida de inmersi\u00f3n temporal<\/td><td>aplicaciones espec\u00edficas con riesgo de inmersi\u00f3n temporal<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La tabla es una interpretaci\u00f3n resumida para proyecto. Los criterios completos, m\u00e9todos de ensayo y condiciones de aplicaci\u00f3n est\u00e1n definidos en IEC 60529.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IP65 e IP66 no significan \u201cbueno\u201d y \u201cmejor\u201d en cualquier situaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La b\u00fasqueda <strong>IP65 IP66<\/strong> suele llevar a la idea de que basta con elegir el n\u00famero mayor. En el primer d\u00edgito, ambos tienen nivel 6 para s\u00f3lidos. La diferencia est\u00e1 en el segundo d\u00edgito: 5 y 6 corresponden a condiciones distintas de exposici\u00f3n al agua.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un dispositivo IP66 puede ser apropiado donde se espera una exposici\u00f3n m\u00e1s intensa a chorros, pero eso no resuelve autom\u00e1ticamente otros riesgos. Si el problema predominante es vandalismo, impacto, corrosi\u00f3n o temperatura extrema, pasar de IP65 a IP66 puede no atacar la causa relevante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adem\u00e1s, la especificaci\u00f3n debe exigir exactamente la condici\u00f3n necesaria, y no el n\u00famero m\u00e1s alto disponible en el cat\u00e1logo. Exigencias desproporcionadas pueden reducir la competencia sin beneficio t\u00e9cnico mensurable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El primer d\u00edgito IP trata s\u00f3lidos y acceso a partes peligrosas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En equipos electr\u00f3nicos exteriores, el nivel 6 suele ser deseable porque corresponde a una condici\u00f3n de envolvente estanca al polvo. Sin embargo, los ambientes interiores pueden permitir clases diferentes dependiendo de la instalaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La elecci\u00f3n debe considerar la exposici\u00f3n real: \u00e1rea administrativa limpia, estacionamiento, muelle, industria con part\u00edculas, ambiente de proceso o instalaci\u00f3n exterior. El proyecto tambi\u00e9n debe considerar si el equipo queda protegido por cubierta, nicho, caja adicional o gabinete t\u00e9cnico.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El segundo d\u00edgito IP trata el agua en condiciones de ensayo espec\u00edficas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lluvia, salpicaduras, chorros, lavado e inmersi\u00f3n son situaciones diferentes. La clasificaci\u00f3n debe ser compatible con la forma de exposici\u00f3n prevista. En portones, muelles, \u00e1reas exteriores y ambientes sujetos a lavado, esto puede cambiar significativamente la especificaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Es importante no extrapolar el c\u00f3digo. IP67, por ejemplo, no significa autom\u00e1ticamente resistencia ilimitada al agua ni aptitud para cualquier profundidad o tiempo de inmersi\u00f3n. El c\u00f3digo est\u00e1 asociado a las condiciones definidas en el ensayo normativo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El grado de protecci\u00f3n IK trata el impacto mec\u00e1nico<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>IEC 62262<\/strong> clasifica la protecci\u00f3n ofrecida por la envolvente frente a impactos mec\u00e1nicos externos. En control de acceso, esto es relevante para lectores instalados en \u00e1reas p\u00fablicas, portones, entradas de edificios, estacionamientos, escuelas, terminales, ambientes industriales y lugares sujetos a vandalismo o impacto accidental.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Algunos niveles conocidos son:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>C\u00f3digo IK<\/td><td>Energ\u00eda de impacto asociada<\/td><\/tr><tr><td>IK07<\/td><td>2 J<\/td><\/tr><tr><td>IK08<\/td><td>5 J<\/td><\/tr><tr><td>IK09<\/td><td>10 J<\/td><\/tr><tr><td>IK10<\/td><td>20 J<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La energ\u00eda de ensayo no debe interpretarse como garant\u00eda de que el equipo resistir\u00e1 cualquier forma de vandalismo. Geometr\u00eda, punto de impacto, montaje, sustrato y repetici\u00f3n de agresiones pueden producir condiciones diferentes de las previstas en el ensayo.<\/p>\n\n\n\n<figure class=\"a3a-mermaid\"><svg id=\"a3a-diagram-1\" width=\"100%\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"flowchart\" style=\"max-width:min(741.53125px, 100%);height:auto;display:block;margin:0 auto\" viewBox=\"0 0 741.53125 603.5\" role=\"graphics-document document\" aria-roledescription=\"flowchart-v2\" aria-labelledby=\"chart-title-a3a-diagram-1\"><title id=\"chart-title-a3a-diagram-1\">Processo de sele\u00e7\u00e3o de classes ambientais para equipamentos de controle de acesso<\/title><style>#a3a-diagram-1{font-family:Roboto,sans-serif;font-size:15px;fill:var(--a3a-diag-text, #0a0a0a);}@keyframes edge-animation-frame{from{stroke-dashoffset:0;}}@keyframes dash{to{stroke-dashoffset:0;}}#a3a-diagram-1 .edge-animation-slow{stroke-dasharray:9,5!important;stroke-dashoffset:900;animation:dash 50s linear infinite;stroke-linecap:round;}#a3a-diagram-1 .edge-animation-fast{stroke-dasharray:9,5!important;stroke-dashoffset:900;animation:dash 20s linear infinite;stroke-linecap:round;}#a3a-diagram-1 .error-icon{fill:var(--a3a-diag-canvas, #ffffff);}#a3a-diagram-1 .error-text{fill:#000000;stroke:#000000;}#a3a-diagram-1 .edge-thickness-normal{stroke-width:1px;}#a3a-diagram-1 .edge-thickness-thick{stroke-width:3.5px;}#a3a-diagram-1 .edge-pattern-solid{stroke-dasharray:0;}#a3a-diagram-1 .edge-thickness-invisible{stroke-width:0;fill:none;}#a3a-diagram-1 .edge-pattern-dashed{stroke-dasharray:3;}#a3a-diagram-1 .edge-pattern-dotted{stroke-dasharray:2;}#a3a-diagram-1 .marker{fill:var(--a3a-diag-stroke, #2e42a2);stroke:var(--a3a-diag-stroke, #2e42a2);}#a3a-diagram-1 .marker.cross{stroke:var(--a3a-diag-stroke, #2e42a2);}#a3a-diagram-1 svg{font-family:Roboto,sans-serif;font-size:15px;}#a3a-diagram-1 p{margin:0;}#a3a-diagram-1 .label{font-family:Roboto,sans-serif;color:var(--a3a-diag-text, #0a0a0a);}#a3a-diagram-1 .cluster-label text{fill:var(--a3a-diag-title, #0124af);}#a3a-diagram-1 .cluster-label span{color:var(--a3a-diag-title, #0124af);}#a3a-diagram-1 .cluster-label span p{background-color:transparent;}#a3a-diagram-1 .label text,#a3a-diagram-1 span{fill:var(--a3a-diag-text, #0a0a0a);color:var(--a3a-diag-text, #0a0a0a);}#a3a-diagram-1 .node rect,#a3a-diagram-1 .node circle,#a3a-diagram-1 .node ellipse,#a3a-diagram-1 .node polygon,#a3a-diagram-1 .node path{fill:var(--a3a-diag-fill, #eef2fd);stroke:var(--a3a-diag-stroke, #2e42a2);stroke-width:1px;}#a3a-diagram-1 .rough-node .label text,#a3a-diagram-1 .node .label text,#a3a-diagram-1 .image-shape .label,#a3a-diagram-1 .icon-shape .label{text-anchor:middle;}#a3a-diagram-1 .node .katex path{fill:#000;stroke:#000;stroke-width:1px;}#a3a-diagram-1 .rough-node .label,#a3a-diagram-1 .node .label,#a3a-diagram-1 .image-shape .label,#a3a-diagram-1 .icon-shape .label{text-align:center;}#a3a-diagram-1 .node.clickable{cursor:pointer;}#a3a-diagram-1 .root .anchor path{fill:var(--a3a-diag-stroke, #2e42a2)!important;stroke-width:0;stroke:var(--a3a-diag-stroke, #2e42a2);}#a3a-diagram-1 .arrowheadPath{fill:var(--a3a-diag-stroke, #0b0b0b);}#a3a-diagram-1 .edgePath .path{stroke:var(--a3a-diag-stroke, #2e42a2);stroke-width:2.0px;}#a3a-diagram-1 .flowchart-link{stroke:var(--a3a-diag-stroke, #2e42a2);fill:none;}#a3a-diagram-1 .edgeLabel{background-color:var(--a3a-diag-canvas, #ffffff);text-align:center;}#a3a-diagram-1 .edgeLabel p{background-color:var(--a3a-diag-canvas, #ffffff);}#a3a-diagram-1 .edgeLabel rect{opacity:0.5;background-color:var(--a3a-diag-canvas, #ffffff);fill:var(--a3a-diag-canvas, #ffffff);}#a3a-diagram-1 .labelBkg{background-color:rgba(255, 255, 255, 0.5);}#a3a-diagram-1 .cluster rect{fill:var(--a3a-diag-surface, #f8f8f8);stroke:var(--a3a-diag-border, #e2e8f0);stroke-width:1px;}#a3a-diagram-1 .cluster text{fill:var(--a3a-diag-title, #0124af);}#a3a-diagram-1 .cluster span{color:var(--a3a-diag-title, #0124af);}#a3a-diagram-1 div.mermaidTooltip{position:absolute;text-align:center;max-width:200px;padding:2px;font-family:Roboto,sans-serif;font-size:12px;background:var(--a3a-diag-canvas, #ffffff);border:1px solid hsl(0, 0%, 90%);border-radius:2px;pointer-events:none;z-index:100;}#a3a-diagram-1 .flowchartTitleText{text-anchor:middle;font-size:18px;fill:var(--a3a-diag-text, #0a0a0a);}#a3a-diagram-1 rect.text{fill:none;stroke-width:0;}#a3a-diagram-1 .icon-shape,#a3a-diagram-1 .image-shape{background-color:var(--a3a-diag-canvas, #ffffff);text-align:center;}#a3a-diagram-1 .icon-shape p,#a3a-diagram-1 .image-shape p{background-color:var(--a3a-diag-canvas, #ffffff);padding:2px;}#a3a-diagram-1 .icon-shape rect,#a3a-diagram-1 .image-shape rect{opacity:0.5;background-color:var(--a3a-diag-canvas, #ffffff);fill:var(--a3a-diag-canvas, #ffffff);}#a3a-diagram-1 .label-icon{display:inline-block;height:1em;overflow:visible;vertical-align:-0.125em;}#a3a-diagram-1 .node .label-icon path{fill:currentColor;stroke:revert;stroke-width:revert;}#a3a-diagram-1 :root{--mermaid-font-family:Roboto,sans-serif;}<\/style><g><marker id=\"a3a-diagram-1_flowchart-v2-pointEnd\" class=\"marker flowchart-v2\" viewBox=\"0 0 10 10\" refX=\"5\" refY=\"5\" markerUnits=\"userSpaceOnUse\" markerWidth=\"8\" markerHeight=\"8\" orient=\"auto\"><path d=\"M 0 0 L 10 5 L 0 10 z\" class=\"arrowMarkerPath\" style=\"stroke-width: 1; stroke-dasharray: 1, 0;\"><\/path><\/marker><marker id=\"a3a-diagram-1_flowchart-v2-pointStart\" class=\"marker flowchart-v2\" viewBox=\"0 0 10 10\" refX=\"4.5\" refY=\"5\" markerUnits=\"userSpaceOnUse\" markerWidth=\"8\" markerHeight=\"8\" orient=\"auto\"><path d=\"M 0 5 L 10 10 L 10 0 z\" class=\"arrowMarkerPath\" style=\"stroke-width: 1; stroke-dasharray: 1, 0;\"><\/path><\/marker><marker id=\"a3a-diagram-1_flowchart-v2-circleEnd\" class=\"marker flowchart-v2\" viewBox=\"0 0 10 10\" refX=\"11\" refY=\"5\" markerUnits=\"userSpaceOnUse\" markerWidth=\"11\" markerHeight=\"11\" orient=\"auto\"><circle cx=\"5\" cy=\"5\" r=\"5\" class=\"arrowMarkerPath\" style=\"stroke-width: 1; stroke-dasharray: 1, 0;\"><\/circle><\/marker><marker id=\"a3a-diagram-1_flowchart-v2-circleStart\" class=\"marker flowchart-v2\" viewBox=\"0 0 10 10\" refX=\"-1\" refY=\"5\" markerUnits=\"userSpaceOnUse\" markerWidth=\"11\" markerHeight=\"11\" orient=\"auto\"><circle cx=\"5\" cy=\"5\" r=\"5\" class=\"arrowMarkerPath\" style=\"stroke-width: 1; stroke-dasharray: 1, 0;\"><\/circle><\/marker><marker id=\"a3a-diagram-1_flowchart-v2-crossEnd\" class=\"marker cross flowchart-v2\" viewBox=\"0 0 11 11\" refX=\"12\" refY=\"5.2\" markerUnits=\"userSpaceOnUse\" markerWidth=\"11\" markerHeight=\"11\" orient=\"auto\"><path d=\"M 1,1 l 9,9 M 10,1 l -9,9\" class=\"arrowMarkerPath\" style=\"stroke-width: 2; stroke-dasharray: 1, 0;\"><\/path><\/marker><marker id=\"a3a-diagram-1_flowchart-v2-crossStart\" class=\"marker cross flowchart-v2\" viewBox=\"0 0 11 11\" refX=\"-1\" refY=\"5.2\" markerUnits=\"userSpaceOnUse\" markerWidth=\"11\" markerHeight=\"11\" orient=\"auto\"><path d=\"M 1,1 l 9,9 M 10,1 l -9,9\" class=\"arrowMarkerPath\" style=\"stroke-width: 2; stroke-dasharray: 1, 0;\"><\/path><\/marker><g class=\"root\"><g class=\"clusters\"><\/g><g class=\"edgePaths\"><path d=\"M304.344,52.644L276.038,58.12C247.732,63.596,191.12,74.548,162.814,83.524C134.508,92.5,134.508,99.5,134.508,103L134.508,106.5\" id=\"L_A_B_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_A_B_0\" data-points=\"W3sieCI6MzA0LjM0Mzc1LCJ5Ijo1Mi42NDM3MTU1MzI3NDk0Mn0seyJ4IjoxMzQuNTA3ODEyNSwieSI6ODUuNX0seyJ4IjoxMzQuNTA3ODEyNSwieSI6MTEwLjV9XQ==\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M399.422,60.5L399.422,64.667C399.422,68.833,399.422,77.167,399.422,84.833C399.422,92.5,399.422,99.5,399.422,103L399.422,106.5\" id=\"L_A_C_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_A_C_0\" data-points=\"W3sieCI6Mzk5LjQyMTg3NSwieSI6NjAuNX0seyJ4IjozOTkuNDIxODc1LCJ5Ijo4NS41fSx7IngiOjM5OS40MjE4NzUsInkiOjExMC41fV0=\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M494.5,54.883L518.014,59.986C541.529,65.089,588.557,75.294,612.072,83.897C635.586,92.5,635.586,99.5,635.586,103L635.586,106.5\" id=\"L_A_D_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_A_D_0\" data-points=\"W3sieCI6NDk0LjUsInkiOjU0Ljg4MjkxODcyMDQzNDAyfSx7IngiOjYzNS41ODU5Mzc1LCJ5Ijo4NS41fSx7IngiOjYzNS41ODU5Mzc1LCJ5IjoxMTAuNX1d\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M134.508,163L134.508,167.167C134.508,171.333,134.508,179.667,144.655,187.759C154.802,195.852,175.096,203.704,185.243,207.631L195.391,211.557\" id=\"L_B_E_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_B_E_0\" data-points=\"W3sieCI6MTM0LjUwNzgxMjUsInkiOjE2M30seyJ4IjoxMzQuNTA3ODEyNSwieSI6MTg4fSx7IngiOjE5OS4xMjA5OTg0NzU2MDk3NSwieSI6MjEzfV0=\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M399.422,163L399.422,167.167C399.422,171.333,399.422,179.667,389.275,187.759C379.128,195.852,358.833,203.704,348.686,207.631L338.539,211.557\" id=\"L_C_E_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_C_E_0\" data-points=\"W3sieCI6Mzk5LjQyMTg3NSwieSI6MTYzfSx7IngiOjM5OS40MjE4NzUsInkiOjE4OH0seyJ4IjozMzQuODA4Njg5MDI0MzkwMiwieSI6MjEzfV0=\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M635.586,163L635.586,167.167C635.586,171.333,635.586,179.667,635.586,187.333C635.586,195,635.586,202,635.586,205.5L635.586,209\" id=\"L_D_F_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_D_F_0\" data-points=\"W3sieCI6NjM1LjU4NTkzNzUsInkiOjE2M30seyJ4Ijo2MzUuNTg1OTM3NSwieSI6MTg4fSx7IngiOjYzNS41ODU5Mzc1LCJ5IjoyMTN9XQ==\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M266.965,265.5L266.965,269.667C266.965,273.833,266.965,282.167,276.343,290.243C285.721,298.32,304.477,306.14,313.855,310.051L323.233,313.961\" id=\"L_E_G_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_E_G_0\" data-points=\"W3sieCI6MjY2Ljk2NDg0Mzc1LCJ5IjoyNjUuNX0seyJ4IjoyNjYuOTY0ODQzNzUsInkiOjI5MC41fSx7IngiOjMyNi45MjQ4Mjg1MDYwOTc2LCJ5IjozMTUuNX1d\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M635.586,265.5L635.586,269.667C635.586,273.833,635.586,282.167,616.263,290.364C596.939,298.561,558.293,306.622,538.97,310.653L519.646,314.683\" id=\"L_F_G_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_F_G_0\" data-points=\"W3sieCI6NjM1LjU4NTkzNzUsInkiOjI2NS41fSx7IngiOjYzNS41ODU5Mzc1LCJ5IjoyOTAuNX0seyJ4Ijo1MTUuNzMwNzU0NTczMTcwOCwieSI6MzE1LjV9XQ==\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M389.883,368L389.883,372.167C389.883,376.333,389.883,384.667,389.883,392.333C389.883,400,389.883,407,389.883,410.5L389.883,414\" id=\"L_G_H_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_G_H_0\" data-points=\"W3sieCI6Mzg5Ljg4MjgxMjUsInkiOjM2OH0seyJ4IjozODkuODgyODEyNSwieSI6MzkzfSx7IngiOjM4OS44ODI4MTI1LCJ5Ijo0MTh9XQ==\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><path d=\"M389.883,470.5L389.883,474.667C389.883,478.833,389.883,487.167,389.883,494.833C389.883,502.5,389.883,509.5,389.883,513L389.883,516.5\" id=\"L_H_I_0\" class=\"edge-thickness-normal edge-pattern-solid edge-thickness-normal edge-pattern-solid flowchart-link\" style=\";\" data-edge=\"true\" data-et=\"edge\" data-id=\"L_H_I_0\" data-points=\"W3sieCI6Mzg5Ljg4MjgxMjUsInkiOjQ3MC41fSx7IngiOjM4OS44ODI4MTI1LCJ5Ijo0OTUuNX0seyJ4IjozODkuODgyODEyNSwieSI6NTIwLjV9XQ==\" marker-end=\"url(#a3a-diagram-1_flowchart-v2-pointEnd)\"><\/path><\/g><g class=\"edgeLabels\"><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_A_B_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_A_C_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_A_D_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_B_E_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_C_E_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_D_F_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_E_G_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_F_G_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_G_H_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"edgeLabel\"><g class=\"label\" data-id=\"L_H_I_0\" transform=\"translate(0, 0)\"><foreignObject width=\"0\" height=\"0\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" class=\"labelBkg\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"edgeLabel\"><\/span><\/div><\/foreignObject><\/g><\/g><\/g><g class=\"nodes\"><g class=\"node default\" id=\"flowchart-A-0\" transform=\"translate(399.421875, 34.25)\"><rect class=\"basic label-container\" style=\"\" x=\"-95.078125\" y=\"-26.25\" width=\"190.15625\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-65.078125, -11.25)\"><rect><\/rect><foreignObject width=\"130.15625\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Local de instala\u00e7\u00e3o<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-B-1\" transform=\"translate(134.5078125, 136.75)\"><rect class=\"basic label-container\" style=\"\" x=\"-126.5078125\" y=\"-26.25\" width=\"253.015625\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-96.5078125, -11.25)\"><rect><\/rect><foreignObject width=\"193.015625\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Exposi\u00e7\u00e3o a s\u00f3lidos e poeira<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-C-3\" transform=\"translate(399.421875, 136.75)\"><rect class=\"basic label-container\" style=\"\" x=\"-88.40625\" y=\"-26.25\" width=\"176.8125\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-58.40625, -11.25)\"><rect><\/rect><foreignObject width=\"116.8125\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Exposi\u00e7\u00e3o \u00e0 \u00e1gua<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-D-5\" transform=\"translate(635.5859375, 136.75)\"><rect class=\"basic label-container\" style=\"\" x=\"-88.0859375\" y=\"-26.25\" width=\"176.171875\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-58.0859375, -11.25)\"><rect><\/rect><foreignObject width=\"116.171875\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Risco de impacto<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-E-7\" transform=\"translate(266.96484375, 239.25)\"><rect class=\"basic label-container\" style=\"\" x=\"-97.890625\" y=\"-26.25\" width=\"195.78125\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-67.890625, -11.25)\"><rect><\/rect><foreignObject width=\"135.78125\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Classe IP necess\u00e1ria<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-F-11\" transform=\"translate(635.5859375, 239.25)\"><rect class=\"basic label-container\" style=\"\" x=\"-97.9453125\" y=\"-26.25\" width=\"195.890625\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-67.9453125, -11.25)\"><rect><\/rect><foreignObject width=\"135.890625\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Classe IK necess\u00e1ria<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-G-13\" transform=\"translate(389.8828125, 341.75)\"><rect class=\"basic label-container\" style=\"\" x=\"-127.5546875\" y=\"-26.25\" width=\"255.109375\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-97.5546875, -11.25)\"><rect><\/rect><foreignObject width=\"195.109375\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Temperatura \/ UV \/ corros\u00e3o<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-H-17\" transform=\"translate(389.8828125, 444.25)\"><rect class=\"basic label-container\" style=\"\" x=\"-107.171875\" y=\"-26.25\" width=\"214.34375\" height=\"52.5\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-77.171875, -11.25)\"><rect><\/rect><foreignObject width=\"154.34375\" height=\"22.5\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table-cell; white-space: nowrap; line-height: 1.5; max-width: 200px; text-align: center;\"><span class=\"nodeLabel\"><p>Montagem e interfaces<\/p><\/span><\/div><\/foreignObject><\/g><\/g><g class=\"node default\" id=\"flowchart-I-19\" transform=\"translate(389.8828125, 558)\"><rect class=\"basic label-container\" style=\"\" x=\"-130\" y=\"-37.5\" width=\"260\" height=\"75\"><\/rect><g class=\"label\" style=\"\" transform=\"translate(-100, -22.5)\"><rect><\/rect><foreignObject width=\"200\" height=\"45\"><div xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"display: table; white-space: break-spaces; line-height: 1.5; max-width: 200px; text-align: center; width: 200px;\"><span class=\"nodeLabel\"><p>Especifica\u00e7\u00e3o por desempenho<\/p><\/span><\/div><\/foreignObject><\/g><\/g><\/g><\/g><\/g><\/svg><figcaption>Processo de sele\u00e7\u00e3o de classes ambientais para equipamentos de controle de acesso<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Un lector exterior necesita m\u00e1s que IP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los lectores de control de acceso suelen instalarse exactamente en la frontera entre ambiente interior y exterior. Adem\u00e1s de lluvia y polvo, pueden recibir sol directo, variaciones t\u00e9rmicas, condensaci\u00f3n, salinidad, impactos e intentos de violaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Por eso, el proyecto debe verificar simult\u00e1neamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>clasificaci\u00f3n IP compatible con agua y s\u00f3lidos;<\/li><li>clasificaci\u00f3n IK compatible con el riesgo de impacto;<\/li><li>rango de temperatura de operaci\u00f3n;<\/li><li>material y acabado de la envolvente;<\/li><li>resistencia a UV cuando est\u00e9 expuesto al sol;<\/li><li>condiciones de instalaci\u00f3n y sellado;<\/li><li>recursos de tamper o detecci\u00f3n de retirada cuando sean requeridos;<\/li><li>compatibilidad de conectores y prensaestopas con la exposici\u00f3n prevista.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un fabricante puede declarar IP65 e IK07 para un lector destinado a ambientes interiores y exteriores hostiles, mientras otro equipo para \u00e1rea p\u00fablica puede llegar a IP66 e IK08. El valor adecuado debe derivarse del lugar y del riesgo, no de la comparaci\u00f3n comercial aislada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">La clasificaci\u00f3n del equipo puede perderse por una instalaci\u00f3n inadecuada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El c\u00f3digo declarado vale para el producto seg\u00fan la configuraci\u00f3n y el montaje evaluados. Perforaciones adicionales, prensaestopas inadecuados, tapa mal cerrada, junta da\u00f1ada, caja de paso incompatible o entrada de cable orientada incorrectamente pueden comprometer la protecci\u00f3n del conjunto instalado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este punto es cr\u00edtico en retrofit y obra. De poco sirve especificar un lector IP66 si el cable entra por una caja sin protecci\u00f3n equivalente y permite agua en la conexi\u00f3n. La ingenier\u00eda debe considerar el recorrido completo del punto: equipo, soporte, caja, conducto, conexi\u00f3n, drenaje cuando corresponda e interfaz con la pared o estructura.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IP no informa resistencia a la corrosi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los ambientes costeros, industriales, qu\u00edmicos o con agentes agresivos requieren un an\u00e1lisis adicional. Una envolvente puede cumplir determinado IP y aun as\u00ed sufrir corrosi\u00f3n prematura en el material, tornillos, conectores o soporte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La especificaci\u00f3n debe tratar materiales, revestimientos y compatibilidad ambiental cuando exista el riesgo. Lo mismo vale para la exposici\u00f3n solar: IP no es una clasificaci\u00f3n de resistencia a UV.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IP tampoco define el rango de temperatura<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un lector IP65 puede tener un rango de operaci\u00f3n diferente al de otro producto con la misma clasificaci\u00f3n. Por tanto, las temperaturas m\u00ednima y m\u00e1xima deben aparecer como requisito separado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En \u00e1reas exteriores, las superficies expuestas al sol pueden alcanzar temperaturas superiores a la temperatura ambiente medida a la sombra. En c\u00e1maras frigor\u00edficas o regiones de baja temperatura, tambi\u00e9n deben considerarse la condensaci\u00f3n y los ciclos t\u00e9rmicos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IK no sustituye requisitos antivandalismo del sistema<\/h2>\n\n\n\n<div class=\"wp-block-a3a-destaque\">\n<p class=\"wp-block-paragraph\">La robustez del lector es solo una capa. La posici\u00f3n de la controladora, la comunicaci\u00f3n, la fijaci\u00f3n, el tamper y la arquitectura tambi\u00e9n determinan la seguridad f\u00edsica del punto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/planejamento\/projeto-de-sistema-integrado-de-seguranca-eletronica\/\">Vea el Proyecto de Seguridad Electr\u00f3nica Integrada<\/a><\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Un c\u00f3digo IK elevado mejora la evidencia de resistencia de la envolvente al impacto, pero no resuelve por s\u00ed solo la seguridad f\u00edsica. Un lector resistente puede seguir siendo vulnerable si la controladora est\u00e1 instalada en el lado no seguro, si el cable puede accederse f\u00e1cilmente o si la cerradura puede ser eludida.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El proyecto de control de acceso debe analizar la barrera completa: posici\u00f3n de la controladora, protocolo del lector, seguridad de la comunicaci\u00f3n, protecci\u00f3n de las interfaces, fijaci\u00f3n y detecci\u00f3n de violaci\u00f3n. <strong>La robustez mec\u00e1nica del lector es solo una capa.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Las controladoras interiores no necesitan la misma clase que el lector exterior<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una mala pr\u00e1ctica es copiar la misma exigencia ambiental para todos los componentes. La controladora normalmente debe quedar en el lado seguro, en un gabinete protegido o sala t\u00e9cnica. El lector, por otro lado, puede quedar directamente expuesto al ambiente exterior.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esto permite especificar requisitos diferentes por componente y evita exigir envolventes extremas donde no existe un riesgo correspondiente. La matriz de equipos debe registrar ambiente y clase necesaria para cada familia: lector, intercomunicador, pulsador, controladora, fuente, gabinete, sensor o interfaz.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IP69 e IP69K exigen cuidado con la terminolog\u00eda<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Existen productos comercializados con clasificaciones relacionadas con lavado a alta presi\u00f3n y alta temperatura. La terminolog\u00eda y la norma de referencia deben verificarse en la ficha t\u00e9cnica: <strong>IP69<\/strong> aparece en el contexto de IEC 60529 consolidada, mientras que <strong>IP69K<\/strong> se asocia hist\u00f3ricamente con referencias espec\u00edficas como DIN\/ISO para veh\u00edculos y equipos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No es recomendable escribir solo \u201cIP69K o superior\u201d en una especificaci\u00f3n sin definir la norma, condici\u00f3n de ensayo y necesidad del proyecto. La clase debe tener trazabilidad normativa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">NEMA e IP no deben convertirse como equivalentes perfectos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En equipos de origen norteamericano pueden aparecer clasificaciones NEMA junto con IP. Los dos sistemas no son id\u00e9nticos y cubren conjuntos de requisitos diferentes. Las tablas de correlaci\u00f3n pueden ayudar en la evaluaci\u00f3n inicial, pero no deben utilizarse para declarar equivalencia autom\u00e1tica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando el proyecto exige una clasificaci\u00f3n espec\u00edfica, la comprobaci\u00f3n debe hacerse mediante la norma y el c\u00f3digo declarados en el producto.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">C\u00f3mo especificar IP e IK sin vincularse a un fabricante<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una especificaci\u00f3n por desempe\u00f1o debe relacionar cada requisito con el entorno. Por ejemplo: lector exterior expuesto directamente a lluvia y polvo con clase IP m\u00ednima compatible; equipo accesible al p\u00fablico con clase IK compatible con el riesgo de impacto; rango de temperatura correspondiente al lugar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La especificaci\u00f3n puede exigir:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>c\u00f3digo IP m\u00ednimo y norma de referencia;<\/li><li>c\u00f3digo IK m\u00ednimo y norma de referencia cuando corresponda;<\/li><li>rango de temperatura de operaci\u00f3n;<\/li><li>condiciones para uso exterior;<\/li><li>materiales\/revestimientos cuando exista corrosi\u00f3n;<\/li><li>resistencia a UV cuando sea relevante;<\/li><li>montaje y accesorios que preserven la clase declarada;<\/li><li>documentaci\u00f3n t\u00e9cnica del fabricante que demuestre los requisitos;<\/li><li>inspecci\u00f3n del montaje durante el comisionamiento.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">El objetivo es dejar claro <strong>por qu\u00e9<\/strong> la clase es necesaria. Esto reduce requisitos arbitrarios y facilita el an\u00e1lisis de equivalencia t\u00e9cnica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAT y SAT deben verificar documentaci\u00f3n e instalaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IP e IK se comprueban principalmente mediante documentaci\u00f3n de producto y ensayos del fabricante\/laboratorio; el comisionamiento de campo no debe improvisar ensayos destructivos de agua o impacto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el FAT, cuando corresponda, se verifican documentaci\u00f3n, modelo, clase declarada y accesorios necesarios. En el SAT, la inspecci\u00f3n debe confirmar montaje, cierre, prensaestopas, cajas, orientaci\u00f3n e integridad de las interfaces que preservan la protecci\u00f3n ambiental.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si la instalaci\u00f3n modifica la envolvente o utiliza accesorios incompatibles, el hecho de que la ficha t\u00e9cnica indique IP65, IP66 o IK10 no garantiza que el conjunto en campo mantenga el desempe\u00f1o previsto.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">C\u00f3mo elegir el grado de protecci\u00f3n en el Proyecto de Control de Acceso<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El <strong>Proyecto de Control de Acceso<\/strong> debe clasificar los ambientes antes de elegir equipos. A partir del lugar, se define la exposici\u00f3n al agua, polvo, impacto, temperatura, vandalismo y corrosi\u00f3n. Solo entonces se establecen los requisitos de cada dispositivo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este enfoque evita dos extremos: equipo subespecificado, que falla prematuramente, y requisito excesivo, que aumenta el costo y reduce la competencia sin necesidad. IP e IK se convierten en criterios de ingenier\u00eda trazables dentro de la especificaci\u00f3n y de la matriz de equipos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Consideraciones finales<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los grados de protecci\u00f3n IP e IK son herramientas objetivas para especificar envolventes, pero miden fen\u00f3menos diferentes. IP trata la protecci\u00f3n contra s\u00f3lidos y agua; IK trata los impactos mec\u00e1nicos. Ninguno de los dos sustituye el an\u00e1lisis de temperatura, UV, corrosi\u00f3n, instalaci\u00f3n, seguridad f\u00edsica o arquitectura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En control de acceso, la clase correcta es aquella justificada por el entorno y por la funci\u00f3n de cada dispositivo. Cuando esa justificaci\u00f3n entra en el proyecto, el c\u00f3digo deja de ser un n\u00famero de cat\u00e1logo y pasa a ser un requisito verificable de desempe\u00f1o.<\/p>\n\n\n\n<div class=\"wp-block-a3a-destaque\">\n<p class=\"wp-block-paragraph\">En el SAT, la clase declarada debe preservarse mediante la instalaci\u00f3n: cajas, prensaestopas, tapas e interfaces forman parte del desempe\u00f1o final.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/implementacao\/comissionamento\/\">Conozca el Comisionamiento de Ingenier\u00eda<\/a><\/p>\n<\/div>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Referencias t\u00e9cnicas<\/summary>\n<p class=\"wp-block-paragraph\">[1] IEC. IEC 60529:1989+AMD1:1999+AMD2:2013 CSV \u2014 Degrees of protection provided by enclosures (IP Code). Disponible en: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/2452\">https:\/\/webstore.iec.ch\/en\/publication\/2452<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] IEC. IEC 62262:2002+AMD1:2021 CSV \u2014 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code). Disponible en: <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71109\">https:\/\/webstore.iec.ch\/en\/publication\/71109<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3] AXIS COMMUNICATIONS. AXIS A4131-E Reader with Keypad \u2014 clasificaciones IP65 e IK07. Disponible en: <a href=\"https:\/\/www.axis.com\/pt-br\/products\/axis-a4131-e\">https:\/\/www.axis.com\/pt-br\/products\/axis-a4131-e<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[4] AXIS COMMUNICATIONS. AXIS I8307-VE Network Video Intercom \u2014 IP66 e IK08. Disponible en: <a href=\"https:\/\/www.axis.com\/pt-br\/products\/axis-i8307-ve\">https:\/\/www.axis.com\/pt-br\/products\/axis-i8307-ve<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[5] AXIS COMMUNICATIONS. Lectores \u2014 dispositivos IP65 e IK07 para condiciones adversas. Disponible en: <a href=\"https:\/\/www.axis.com\/pt-br\/products\/readers\">https:\/\/www.axis.com\/pt-br\/products\/readers<\/a><\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Preguntas frecuentes<\/summary>\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-o-que-significa-grau-de-prote-o-ip-9b3f07b4\"><strong class=\"schema-faq-question\">\u00bfQu\u00e9 significa grado de protecci\u00f3n IP?<\/strong> <p class=\"schema-faq-answer\">Es la clasificaci\u00f3n definida por IEC 60529 para la protecci\u00f3n proporcionada por la envolvente contra el acceso a partes peligrosas y la entrada de objetos s\u00f3lidos y agua, conforme a los d\u00edgitos del c\u00f3digo.<\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-qual-a-diferen-a-entre-ip65-e-ip66-fb2a3b32\"><strong class=\"schema-faq-question\">\u00bfCu\u00e1l es la diferencia entre IP65 e IP66?<\/strong> <p class=\"schema-faq-answer\">Ambos tienen el primer d\u00edgito 6, relacionado con la condici\u00f3n de protecci\u00f3n contra polvo. La diferencia est\u00e1 en el segundo d\u00edgito: IP66 contempla una condici\u00f3n de ensayo de agua m\u00e1s severa que IP65. Esto no significa que IP66 sea superior para todos los riesgos.<\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-o-que-significa-ik10-588f91a9\"><strong class=\"schema-faq-question\">\u00bfQu\u00e9 significa IK10?<\/strong> <p class=\"schema-faq-answer\">IK10 es una clase de IEC 62262 asociada a una energ\u00eda de impacto de 20 J en el ensayo normativo. Indica resistencia de la envolvente al impacto, pero no garantiza protecci\u00f3n contra cualquier forma de vandalismo.<\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-ip65-significa-que-o-equipamento-pode-ficar-ao-t-4f212712\"><strong class=\"schema-faq-question\">\u00bfIP65 significa que el equipo puede instalarse a la intemperie?<\/strong> <p class=\"schema-faq-answer\">La clasificaci\u00f3n IP es un indicador importante, pero la aptitud para uso exterior tambi\u00e9n depende de temperatura, UV, corrosi\u00f3n, montaje, accesorios y dem\u00e1s condiciones declaradas por el fabricante.<\/p><\/div><div class=\"schema-faq-section\" id=\"faq-question-ip-e-ik-devem-ser-iguais-para-todos-os-component-cbed7846\"><strong class=\"schema-faq-question\">\u00bfIP e IK deben ser iguales para todos los componentes del control de acceso?<\/strong> <p class=\"schema-faq-answer\">No. El lector exterior, la controladora en un \u00e1rea t\u00e9cnica, el gabinete de la fuente y otros dispositivos pueden tener exposiciones diferentes. El proyecto debe especificar requisitos por componente y ambiente.<\/p><\/div><\/div>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Materiales t\u00e9cnicos complementarios<\/summary>\n<h4 class=\"wp-block-heading\">Servicios relacionados<\/h4>\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/planejamento\/projeto-de-controle-de-acesso\/\">Proyecto de Control de Acceso<\/a><\/li><li><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/planejamento\/projeto-de-sistema-integrado-de-seguranca-eletronica\/\">Proyecto de Seguridad Electr\u00f3nica Integrada<\/a><\/li><li><a href=\"https:\/\/a3aengenharia.com.br\/servicos\/implementacao\/comissionamento\/\">Comisionamiento de Ingenier\u00eda<\/a><\/li><\/ul>\n\n<h4 class=\"wp-block-heading\">Contenidos principales sobre el tema<\/h4>\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/a3aengenharia.com.br\/conteudo\/guias-tecnicos\/guia-completo-sobre-controle-de-acesso\/\">Sistema de Control de Acceso: tipos, tecnolog\u00edas, normas y proyecto<\/a><\/li><\/ul>\n\n<h4 class=\"wp-block-heading\">Contenidos t\u00e9cnicos relacionados<\/h4>\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/a3aengenharia.com.br\/conteudo\/artigos-tecnicos\/controladora-de-acesso-como-funciona-io-capacidade-arquitetura\/\">Controladora de acceso: funcionamiento, I\/O, capacidad y arquitectura<\/a><\/li><li><a href=\"https:\/\/a3aengenharia.com.br\/conteudo\/artigos-tecnicos\/osdp-x-wiegand-controle-de-acesso\/\">OSDP vs. Wiegand: seguridad y criterios de proyecto<\/a><\/li><li><a href=\"https:\/\/a3aengenharia.com.br\/conteudo\/artigos-tecnicos\/manutencao-sistemas-controle-de-acesso\/\">Mantenimiento de sistemas de control de acceso<\/a><\/li><li><a href=\"https:\/\/a3aengenharia.com.br\/conteudo\/artigos-tecnicos\/comissionamento-controle-de-acesso-iec-60839\/\">Comisionamiento de sistemas de control de acceso conforme a IEC 60839<\/a><\/li><\/ul>\n<\/details>\n","protected":false},"excerpt":{"rendered":"<p>Grados de protecci\u00f3n IP e IK aplicados al control de acceso: IEC 60529, IEC 62262, IP65 vs. IP66, IK07\u2013IK10 y criterios de especificaci\u00f3n.<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"template":"","meta":{"_a3a_global_related_solutions":[],"_a3a_global_related_services":[],"_a3a_global_related_materials":[],"_a3a_post_lang":"es-es","_a3a_translation_group_id":"5b19d9b2-5ace-4142-9edc-192ecd440ce5","_a3a_i18n_canonical_slug":"grados-proteccion-ip-ik-control-acceso-lectores-equipos","_a3a_lang_url_en-us":"","_a3a_lang_url_es-es":""},"categories":[],"segments":[],"mercados":[],"etapas":[],"class_list":["post-75272","articles","type-articles","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/articles\/75272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/types\/articles"}],"author":[{"embeddable":true,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/articles\/75272\/revisions"}],"predecessor-version":[{"id":75274,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/articles\/75272\/revisions\/75274"}],"wp:attachment":[{"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/media?parent=75272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/categories?post=75272"},{"taxonomy":"segments","embeddable":true,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/segments?post=75272"},{"taxonomy":"mercados","embeddable":true,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/mercados?post=75272"},{"taxonomy":"etapas","embeddable":true,"href":"https:\/\/a3aengenharia.com\/es-es\/wp-json\/wp\/v2\/etapas?post=75272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}